Rupture from Cavernous Internal Carotid Artery Pseudoaneurysm 11 Years After Transsphenoidal Surgery
Background: Bioabsorbable plates are frequently utilized in the repair of skull base defects following transsphenoidal operations. Traumatic intracranial pseudoaneurysms are a rare complication of trans- sphenoidal surgery. To date, iatrogenic carotid pseu- doaneurysm associated with the use of an absorb- able plate has been reported once. Results A 57-year-old man with a large nonfunctional pituitary macroadenoma underwent an endoscopic transsphenoidal operation with gross total resection. An absorbable plate was placed extradurally to re- construct the sellar floor. He experienced delayed repeated epistaxis, followed by a right middle cere- bral artery distribution embolic stroke. Computed to- morgraphy (CT) angiogram 6 weeks postoperatively revealed a 6 × 4 mm pseudoaneurysm located on the medial wall of the right cavernous internal carotid artery. Stent coiling was used to successfully obliter- ate the pseudoaneurysm, and the patient fully recov- ered. Conclusion Delayed erosion of the carotid artery wall caused by a plate used to reconstruct the sellar floor may manifest with epistaxis or embolic stroke. The authors’ preference is to avoid insertion of a rigid plate for sellar floor reconstruction in the absence of intraoperative cerebrospinal fluid (CSF) leaks, un- less it is required to buttress a large skull base defect. Short-segment embolization with stent coiling is the preferred treatment option for carotid pseudoaneu- rysms following transsphenoidal operations. Keywords: cavernous, carotid, pseudoaneurysm, ar- tery Introduction: The transsphenoidal approach is the most commonly utilized operation for the surgical treatment of sellar lesions and is a relatively safe op- eration in experienced centers.1 Following resection of pituitary adenomas and other sellar tumors, many surgeons utilize absorbable plates to reconstruct the bony sellar floor to serve as a buttress for the sellar contents and repair construct. Although usually safe, vascular injury in conjunction with insertion of rigid plates following sellar tumor resection has been de- scribed once before.2 Common complications of transsphenoidal opera- tions include endocrine abnormalities and cerebro- spinal fluid (CSF) leaks.3 Vascular injury is a rare but serious complication of transsphenoidal surgery en- countered in 0.8 to 1.1% of cases, with an associated mortality of nearly 30%.4,5,6 The majority of vascu- lar injuries are identified at the time of surgery, usu- ally resulting from direct injury to the internal carotid artery during resection of tumor within the cavern- ous sinus or upon opening of the dura, often result- ing in profuse arterial hemorrhage.6,7,8,9 Other de- scribed vascular complications include vasospasm, carotid thrombosis, cavernous sinus thrombosis, embolism, caroticocavernous fistula, or pseudoan- eurysm.2,3,7,8,10,11,12,13,14,15,16,17,18,19 Postoperative carotid pseudoaneurysm, though rare, represents a grave risk to the patient if unrecognized. It may lead to delayed hemorrhagic or embolic com- plications when the patient is no longer in a moni- tored hospital setting. This case report highlights the importance of rapid diagnosis and treatment of these lesions. We present a rare case of delayed pseudo- aneurysm and embolic stroke following erosion of a rigid plate into the cavernous internal carotid artery. Case Report: A 57-year-old man with a nonfunction- al pituitary macroadenoma causing vision loss un- derwent a gross total, endoscopic transsphenoidal resection (Fig. 1). The tumor was invading the right cavernous sinus wall. During the procedure to resect
Tom Morrison
To read the full article Download Full Article